Table 5 shows some call progress tones with on/off times; 0.25/0.25 being 250 ms on, 250 ms off on a repeating basis. For example, dial tones as shown in the table are usually "on" continuously and last until the first dial digit is received by the switching system. Line Busy, on the other hand, is turned off and on at a rate of l Hz with a 50% duty cycle, or an interruption rate of
MX566AKQ Price| Parameter | Symbol | Conditions | Ratings | Unit |
| Collector-to-Base Voltage | VCBO | | 1600 | V |
| Collector-to-Emitter Voltage | VCEO | | 800 | V |
| Emitter-to-Base Voltage | VEBO | | 5 | V |
| Collector Current | IC | | 15 | A |
| Collector Current (Pulse) | ICP | | 35 | A |
| | | | 3 0 | W |
| Collector Dissipation | Pc | Tc=251C | 85 | W |
| Junction Temperature | Tj | | 150 | lc |
| Storage Temperature | Tstg | | -55 to +150 | 1C |
| | | | |
MX566AKQ on stock| PARAMETER | CONDITIONS |
| Input Pulse Levels | 0.6V t0 0.7Vcc |
| Input Rise and Fall Times | 3.0 ns |
| Input and Output Timing Reference Level | 1.4V |
| | CL=30pF+lTTL Load(45/55/70ns) |
| Output Load | CL=lOOpF+lTTL Load(Load for 100ns) |
| |
| SYMBOL | PARAMETER | CONDITIONS | MIN | MAX | UNIT |
| Vcc | supply voltage | | -0.5 | +4.6 | V |
| IIK | input diode current | Vl<0 | | -50 | mA |
| VI | input voltage | | -0.5 | +4.6 | V |
| IOK | output diode current | VO > Vcc or Vo < 0 | | +50 | mA |
| VO | output voltage | note 1 | -0.5 | Vcc+ 0.5 | V |
| Power-down mode; note 2 | -0.5 | +4.6 | V |
| 10 | output source or sink current | VO=0 to Vcc | | +50 | mA |
| lcc, IGND | Vcc or GND current | | | +100 | mA |
| Tstg | storage temperature | | -65 | +150 | IC |
| Ptot | power dissipation | Tamb = -40 to +85 IC; note 3 | | 500 | mW |
| | | | | |