An error flag output, indicating when output volt- age drops out of regulation, often due to the falling batteries on the input, can be used for a power-on reset. A logic-controlled shutdown input enables the regulator to be switched on and off. The part may be configured for a fIxed output voltage or programmed from l.235V t0 11V with an external pair of resistors. The part comes in 8- pin DIP or SO packages.
| MAX. | DESIGN LIMITS | APPROXJ |
| D (mm) COATED | VRMS | l HOLD | OHMS |
| 5.5 | 600 15 | 5 mA 150 mA | 2000 13 |
| 6.5 | 600 15 | 7mA 200 mA | 1200 8 |
| 8 | 600 15 | 10 mA 275 mA | 850 6 |
| 9.5 | 600 15 | 13 mA 350 mA | 500 4 |
| 11 | 600 15 | 20 mA 450 mA | 350 2.5 |
| 12 5 | 600 15 | 22 mA 500 mA | 250 2 0 |
| 14 5 | 600 15 | 30 mA 650 mA | 200 1 5 |
| 16 | 600 15 | 35 mA 800 mA | 150 1 2 |
| | | |