| | | Limit Values TA = 250C | Limit Values TA = -55 t0 125 0C | |
| Parameter | Symbol | mln | typ | max | min | max | Unit |
| Input impedance f -l kHz | zl | | 3 | | | | MQ |
| Open-Ioop voltage gain f-lkHz RL=10 kQ,f=1 kHz f-lMHz | Gvo Gvo Gvo | 80 | 83 88 43 | | 75 | | dB dB dB |
| Common-mode input voltage range | c | +2 | | Vs -2 | +3 | Vs -3 | V |
| Common-mode rejection RL=2 kQ | kCMR | 75 | 80 | | 70 | | dB |
| Supply voltage rejection Gv =100 | kSVR | | 25 | 200 | | 200 | LiV/V |
| Temperature coefficient of Vio RG = 50Q Temperature coefficient of Iio RG = 50Q | ayio ano | | 12 50 | 50 | | 50 | yWK pA/K |
| Slew rate of Va for non-inverting operationi) (see TAA 765, test circuit l) Slew rate of Vo for inverting operationi) (see TAA 765, test circuit 2) | SR SR | | 9 18 | | | | WlrS wlls |
| Output saturation voltage IQ = 10 mA | VOsal | | | 1 | | | V |
| Output reverse current | IQR | | | 1 | | 5 | UA |
| | | | | | | |
. Package Dimension: L 7.1 mm x W 4.7 mm x H 2.8 mm . Compatible to the latest lrDA lrPHY Standard . CIR Remote Control Operation: Typical Transmission Range 8 m Using Standard RC-Receivers. Receives RC-Commands with Typical Specified Sensitivity. . SMD Side View